J063, Panic and Intrusion Alarm Replacement and Monitoring, Various Clinics - Portland Veterans Affairs Healthcare System, Dept of Veterans Affairs
See the original posting, the buyer’s contact details, and thousands more contracts like this one
Free account. Already have one? Log in
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services: Title: Panic and Intrusion Alarm Replacement and Monitoring NAICS Code: 561621, Security Systems Services (except Locksmiths) Locations: Fairview VA Clinic, 1800 NE Market Drive, Fairview, OR 97024 Hillsboro VA Clinic,1925 NE Stucki Ave, 3rd and 4th Floor, Hillsboro, OR, 97006 West Linn VA Clinic, 1750 SW Blankenship Road, Suite 300, West Linn, OR 97068 The Dalles CBOC, 704 Veterans Drive, The Dalles, OR 97058 Bend CBOC, 2650 NE Courtney Drive, Bend, OR, 97701 Salem CBOC, 1750 McGilchrist Street SE, Salem, OR 97302 Tasks: Within 30 days, upon award of the contract, the contractor shall remove, install, and test all new components at each location. This should include, keypads, panels, motion sensors, and wireless panic alarms, to the quantity provided at each location. Motion sensors must be based off of PIR and/or Microwave Technology. Sensors should range in detection distance of 40 to 200 feet depending on the area being covered. Some areas will require 360-degree sensors due to cross areas. Sensors should comprise of anti-masking technology where available. Once installed, Contractor shall provide alarm monitoring 24/7. All Security Systems and components must have the ability to be live tested with the monitoring station every month. This will include individual panic alarms, motion sensors, door contacts, and any other form of input. All systems must have the ability to a…
Similar open contracts
G003--Aqua Therapy
THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding th…
J045--Sources Sought/RFI, Including Industry Days WV VA Medical Centers Facility Maintenance & Repairs BPA RFI Clarksburg, Beckley, and Huntington WV VAMC Mechanical, Plumbing, and Electrical Systems
Sources Sought Notice Sources Sought Notice Page 9 of 9 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 2 General Summary: Department of Veterans Affairs, Veterans Health Admin…
Y1DA--544-355 Construct Behavioral Health Center of Excellence (VA-26-00069876)
INTRODUCTION: This Sources Sought Notice is for market research and information purposes only at this time and shall not be construed as a solicitation or as an obligation on the part of the Departmen…
6515--VISN 8 Situate Detection System
Sources Sought Notice Sources Sought Notice Page 5 of 5 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 5 THIS IS A REQUEST FOR INFORMATION NOTICE ONLY. This is not a solicitat…
C211--589A6-24-410, Replace MDP Panel Bld 89| EKH
Sources Sought Notice Page 3 of 4 Sources Sought Notice Page 1 of 4 DESCRIPTION Sources Sought Notice Page 4 of 4 Sources Sought Notice Page 1 of 4 Page 1 of Request for Information (RFI) 36C25526Q001…
Re-slurry and Re-stripe Bldg. 88 and 98 Parking Lots
Sources Sought Notice ONLY 36C26126Q1261 No Solicitation is currently Available. Please provide answers to Questions a-e listed on Pages 3-4 to determine your capability to meet this construction requ…