Federal Contract

Z2DA--589A7-23-306 Renovate Bldg. 5 & 5B for Mental Health FY27 NRM

See the original posting, the buyer’s contact details, and thousands more contracts like this one

Free account. Already have one? Log in

Get started

Agency

VETERANS AFFAIRS, DEPARTMENT OF

NAICS Code

236220

Set-Aside

SDVOSBC

Department

VETERANS AFFAIRS, DEPARTMENT OF

Solicitation Type

Solicitation

Solicitation #

36C25526R0171

PSC Code

Z2DA

Division

255-NETWORK CONTRACT OFFICE 15 (36C255)

Performance State

KS

Posted

Mon, September 14, 2026

Response Deadline

Mon, October 19, 2026

Description

Contractor shall perform construction and renovation of the existing space in Building 5 &/or 5B at the Robert J. Dole VA Medical Center campus. This project will prepare approximately 1,100 SF of existing space in building 5 and/or 5B for use as a same day access mental health clinic in adherence to VHA directive 1231(2) & VHA Handbook 1160.1. This project shall be executed in a manner, following the sequence defined in the design narrative, to maintain continuous operations of adjacent VA clinical functions and medical center functionality throughout construction. All construction work shall be performed in full compliance with the complete set of bidding documents, including all contract drawings, specifications, and design narratives associated with this solicitation necessary to convert the existing space into four exam rooms, a combined waiting/reception area, a relocated police office, and associated support spaces. The general contractor shall furnish all labor, supervision, materials, tools, and equipment necessary to execute the required scope of work. Construction will consist of, but is not limited to, the following: � Selective demolition of existing interior partitions, ceilings, finishes, and elements required for new clinic layout. � Installation of new interior finishes including flooring, wall finishes, ceilings, trim, and casework. � Implementation of therapeutic design features, including calm color schemes, anchored artwork, secure hardware, and achieving a minimum STC-45 acoustic rating for exam room partitions. � Installation of new wall-mounted lavatories in each exam room. Routing new domestic hot and cold water from adjacent restrooms and trenching new water lines across the corridor to existing tin-in points. � Rebalancing and modifying HVAC systems; reusing the existing rooftop AHU serving the building; relocating or adding diffusers/grilles; installing ligature-resistant diffusers in exam rooms � Providing new electrical receptacles, dat

Similar open contracts