LOP Fire Protection and Unwatering Pump System
See the original posting, the buyer’s contact details, and thousands more contracts like this one
Free account. Already have one? Log in
Description
The U.S. Army Corps of Engineers (USACE) Portland District has a requirement for an open-market, FOB destination supply procurement of a commercial fire protection and unwatering pumping system for Lookout Point Dam in Lane County, Oregon. As part of a planned deep drawdown of the Lookout Point reservoir, the penstock will be dewatered and the plant�s normal service-water supply temporarily removed, disabling transformer cooling and fire protection while primary power is back fed from the transmission line. To sustain fire protection and support unwatering operations during this period, USACE intends to procure new equipment and associated piping, including but not limited to the following: One 650 GPM vertical pump/motor assembly at 200 ft total dynamic head (?50 HP) and one 2000 GPM vertical pump/motor assembly at 51 ft total dynamic head (?20 HP), both water?lubricated vertical line?shaft units designed in accordance with AWWA E103 and HI 9.1�9.5. A complete fire protection pumping package, to include a UL?listed fire pump controller for a 50 HP, 480 VAC motor; a jockey pump system (0.25 HP, nominal 90 psi); a manual transfer switch for dual fire/unwatering service; and new overload protection compatible with an existing 125A Westinghouse AB DE?ION breaker panel. Associated 10?inch and 6?inch Schedule 40 carbon steel piping, flanges, fittings, valves, pressure relief and pressure regulating valves, and accessories in accordance with ASME B16.5/B31.3, AWWA C500/C517/C530, and the applicable ASTM, ANSI, NEMA, NFPA, and UL standards. The North American Industry Classification System (NAICS) code for this procurement is 333914 Measuring, Dispensing, and Other Pumping Equipment Manufacturing, with a small business size standard of 750 employees. This procurement is set-aside, 100% for small business concerns. This synopsis is not a request for quotes (RFQ), proposals (RFP), or an invitation for bids (IFB). This is a pre-solicitation notice indicating that a solicitati…
Similar open contracts
Lookout Point Powerhouse Drawdown Transformer Cooling Water Supply
The U.S. Army Corps of Engineers (USACE) Portland District has a requirement for an FOB destination supply procurement of a commercial 20-ton refrigerated closed-loop water chiller system for a large …
Bonneville Powerhouse II Unwatering Pump Replacement
The U.S. Army Corps of Engineers (USACE) Portland District (NWP) has a requirement for Unwatering Pump Replacement at the Bonneville Lock and Dam Powerhouse II. Contractor access to the work site will…
Bonneville Powerhouse II Unwatering Pump Replacement
The U.S. Army Corps of Engineers (USACE) Portland District (NWP) has a requirement for Unwatering Pump Replacement at the Bonneville Lock and Dam Powerhouse II. Contractor access to the work site will…
Lookout Point DGA supply and incidental install
The U.S. Army Corps of Engineers (USACE) Portland District has a requirement for a commercial, open-market, FOB destination supply procurement to supply 3 online Dissolved Gas Analysis (DGA) monitorin…
John Day Dam Powerhouse HVAC Upgrades
The U.S. Army Corps of Engineers (USACE) Portland District (NWP) has a requirement for HVAC upgrades at the John Day Dam (JDA) Powerhouse. JDA is approximately 109 miles east of Portland, Oregon, and …
LOP Fire Protection and Unwatering Pump System
08/20/2026: Please see attached solicitation. 09/03/2026: Please see attached amendment 1 and conformed amendment 1.