Federal Contract

Spectroradiometer With Specialized Lens for Characterizing Head Mounted Displays

See the original posting, the buyer’s contact details, and thousands more contracts like this one

Free account. Already have one? Log in

Get started

Agency

FOOD AND DRUG ADMINISTRATION

NAICS Code

334516

Department

HEALTH AND HUMAN SERVICES, DEPARTMENT OF

Solicitation Type

Combined Synopsis/Solicitation

Solicitation #

FDA_RFQ_CDRH_2026_133605

PSC Code

6640

Division

FDA OFFICE OF ACQ GRANT SVCS

Performance State

MD

Posted

Tue, September 8, 2026

Response Deadline

Mon, September 14, 2026

Description

Notice of Combined Synopsis/Solicitation. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation; quotes are being requested, and a separate written solicitation will not be issued. Background: The procurement is to support regulatory science tools development for the Interventional, Radiological Imaging and Visualization program. Developing measurement methodologies for technical performance is critical for consistent evaluation of image visualization on head mounted displays. Specifically, the procurement is for a spectroradiometer to precisely measure and evaluate the spectrum and color performance of image quality of augmented and virtual reality head mounted displays that are increasingly being incorporated in medical devices across the Office of Product Evaluation and Quality (OPEQ). The quantitative measurements from the spectroradiometer will allow for developing image quality regulatory science tools for a wider range image quality parameters across the full range of device types, opposed to only measuring luminance values. The specialized lens assembly on the spectroradiometer mimics the human visual system, which is critical for determining the image quality seen by the user. This will align the Office of Science and Engineering Laboratories (OSEL) instrumentation with FDA recognized standards, such as the International Electrotechnical Commission (IEC), for head mounted displays, which is essential for the OSEL mission of developing regulatory science tools. Minimum Performance Requirements: Item 1: Spectroradiometer Optical Specifications: � Wavelength range: at least 380-780 nm � Sensor size: at least 512 elements � Detector type for spectroradiometer: back-thinned and cooled CCD � Spectral resolution/Spectral bandwidth: < 5 nm, option for variable resolution preferable � Datapoint interval/Spectral reporting: 1 nm or less � Digital

Similar open contracts