Federal Contract

B-21 Field Training Detachment Facility, Dyess AFB-OT Feasibility & Business Feedback

See the original posting, the buyer’s contact details, and thousands more contracts like this one

Free account. Already have one? Log in

Get started

Agency

DEPT OF THE ARMY

NAICS Code

236220

Department

DEPT OF DEFENSE

Solicitation Type

Sources Sought

Solicitation #

W9126G28RB210

PSC Code

Y1JZ

Division

W076 ENDIST FT WORTH

Performance State

TX

Posted

Tue, October 13, 2026

Response Deadline

Tue, October 27, 2026

Description

SUBJECT: Sources Sought Notice/RFI �B-21 Field Training Detachment Facility, Dyess AFB DISCLAIMER: This Sources Sought (SS) is for planning and market research purposes only and does not constitute a Request for Proposals (RFP) or an Invitation for Bids (IFB). This notice is issued under the authority of 10 U.S.C. � 2808a (Other Transaction Authority for Construction and Repair) and is not subject to the Federal Acquisition Regulation (FAR). No solicitation is available at this time. The Government will not pay for any information submitted in response to this notice. PURPOSE: The U.S. Army Corps of Engineers (USACE), Fort Worth District, is conducting active public market intelligence to gauge industry interest, capacity, and capability from commercial construction firms, design-builders, and Non-Traditional Defense Contractors (NDCs). The intent is to gather critical feedback regarding advanced commercial construction methodologies, project delivery risks, and acquisition preferences to support our upcoming project delivery selection. PROJECT DESCRIPTION This project will construct a two-story, approximately 55,617 gross square foot Field Training Detachment facility for B-21 maintenance training at Dyess Air Force Base, Texas, with an estimated Construction Cost Limitation (CCL) of $66,200,000. The facility will feature a steel-frame structure with a metal roof, concrete masonry unit exterior walls, and a drilled concrete pier foundation system designed for local expansive soil conditions. Functional requirements include high bay trainers and classrooms for B-21 maintenance, substantial secure space constructed in compliance with Intelligence Community Directive (ICD) 705 standards with construction security surveillance, a 440-ton HVAC capacity, ducted communications, utilities, and associated site infrastructure and paving. INSTRUCTIONS TO INDUSTRY Review Attached Project Information Packet (PIP): Interested firms are directed to review the attached document. T…

Similar open contracts