Federal Contract

Humidifier Heater Base Sources Sought

See the original posting, the buyer’s contact details, and thousands more contracts like this one

Free account. Already have one? Log in

Get started

Agency

VETERANS AFFAIRS, DEPARTMENT OF

NAICS Code

339112

Department

VETERANS AFFAIRS, DEPARTMENT OF

Solicitation Type

Sources Sought

Solicitation #

36C25227Q0090

PSC Code

6515

Division

252-NETWORK CONTRACT OFFICE 12 (36C252)

Performance State

WI

Posted

Tue, November 10, 2026

Response Deadline

Mon, November 23, 2026

Description

THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Humidifier Heater base, Humidifier Sensor Cartridge, and Humidifier Expiratory Heater to the , Captain James A. Lovell Federal Health Care Center in North Chicago, IL. General Requirements: Brand Name or Equal The below products are known to meet the governments needs all equal parts will be considered. 950 Humidifier Heater base, 950 Humidifier Sensor Cartridge, and 950 Humidifier Expiratory Heater Wire Adapter or Equal Salient Characteristics: Therapy Profiles: Must support Invasive ventilation Must support Noninvasive ventilation Must support Nasal High Flow therapy. Temperature Probes: Must have no external temperature probes Must incorporate internal temperature probes that do not require special disinfection processing Circuit Compatibility: Must be compatible with single heated circuits for non-invasive ventilation. Must be compatible with double heated circuits for invasive ventilation. User Interface: Must have a simple user interface Must include touch screen monitors to create setting modifications Must allow mode changes Must allow comfort setting adjustments Must display and troubleshoot alarms Must provide access to Information and Service menus Alarms: Must have built-in alarms for various conditions including but not limited to: 1. High Temperature alarms 2. Low Temperature alarms 3. Water Out alarms 4. Circuit Disconnect alarms 5. Reverse Gas Flow alarms 6. System check alarms Compatibility: Must be compatible with all ventilation and gas flow delivery devices that is currently used at FHCC, Specificall…

Similar open contracts