Federal Contract

Design-Build-to-Budget � Fort McCoy Indoor Multipurpose Athletic Facility - Army Combat Fitness Testing

See the original posting, the buyer’s contact details, and thousands more contracts like this one

Free account. Already have one? Log in

Get started

Agency

DEPT OF THE ARMY

NAICS Code

236220

Department

DEPT OF DEFENSE

Solicitation Type

Presolicitation

Solicitation #

W912QR27RA005

PSC Code

Y1FB

Division

W072 ENDIST LOUISVILLE

Performance State

WI

Posted

Fri, November 13, 2026

Response Deadline

Thu, December 3, 2026

Description

DESCRIPTION: The U.S. Army Corps of Engineers (USACE), Louisville District intends to issue Request for Proposal (RFP) W912QR27RA005. This project will utilize a Design-Build-to-Budget delivery method to provide a new Soldier Fitness Training and Testing Facility to contain a 54,600 SF multipurpose athletic field via an enclosed structure at Fort McCoy, WI. The Design-Build Contractor shall design and construct the multipurpose facility housing the athletic field to result in a complete and usable facility including all permitting, sitework, and utilities. The facility will consist of an indoor 200-meter rubberized running track and turf infield sized according to Army Techniques Publication (ATP) 7-22.01 Holistic Health and Fitness Training requirements for completing the annual Army Combat Fitness Testing (ACFT). The 200-meter rubberized track will consist of three 4-foot lanes with the lanes striped. Once this project is completed it will be recognized as a permanent facility on Fort McCoy. Supporting facilities include site development, modification to existing improvements, utilities and connections, lighting, paving, sidewalks, storm drainage, information systems, landscaping and signage. Consistent temperature control inside the facility shall be provided by self-contained systems. ATFP measures in accordance with the Department of Defense (DoD) Antiterrorism for Buildings will be provided. A life safety analysis of the facility shall be conducted to determine compliance with UFC, IBC, and NFPA codes and standards. A new addressable fire alarm system shall be installed in the facility that is compatible with the existing base fire alarm reporting system. Comprehensive building design services shall be required. Accessibility for individuals with disabilities shall be required. The multipurpose athletic facility will be periodically occupied and shall require adequate clearance and circulation for personnel, maintenance and operations. This is not a continuous…

Similar open contracts