Federal Contract

X-ray imaging detector system

See the original posting, the buyer’s contact details, and thousands more contracts like this one

Free account. Already have one? Log in

Get started

Agency

ENERGY, DEPARTMENT OF

NAICS Code

334517

Department

ENERGY, DEPARTMENT OF

Solicitation Type

Solicitation

Solicitation #

SLAC_369006_Xray_Imaging_Detector_System

PSC Code

AJ12

Division

SLAC Natl Accel Lab -DOE Contractor

Performance State

CA

Posted

Mon, October 12, 2026

Response Deadline

Fri, October 16, 2026

Extended to Oct 30, 2026 by a later notice

Description

SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions. The follow has been attached for you to complete and review: Requested for Quote: Please provide a price and lead time quotation by 10/16/2026. Technical Evaluation Factors Listed Below: Applicable for hard and high-energy X-ray diffraction greater than 20 keV. Minimum active area of 40 cm x 40 cm. 150 micron pixel size. Amorphous silicon sensor. Flat-panel detector configuration. Required item(s) are listed below: XRD 4343CT-F22-C-000 Imaging Grade digital X-ray detector Quantity: 1 EA XRD-EPS 215W power supply Quantity: 1 EA XRD-EP AC cable Quantity: 1 EA XRD-EPS-B2 DC cable, 50 ft / 15.25 m Quantity: 1 EA XRD-FGX extension cable, 50 ft / 15.25 m Quantity: 1 EA XRD FG(E) OPTO - PCIe Frame Grabber V4 Quantity: 1 EA XRD-FGX-PC connection cable, 25 ft / 7.6 m Quantity: 1 EA Quote is for product only; no on-site services permitted. Source selection will be based on Lowest Priced Technically Acceptable Method and best Lead-Time. Please provide a price and lead time quotation by 10/16/2026. Send quote to Cheryl.stafford@slac.stanford.edu. Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions? Buy American Act Certification (BAA) applies to awards over $15,000 unit price. Representations & Certifications Rider is required. Once completed the Reps and Certs is valid for one year until renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return. Please include in your proposals the Harmonized Tariff Sch…

Notice history (3)

  1. Oct 12, 2026SolicitationDue Oct 16, 2026Viewing
  1. Oct 12, 2026SolicitationDue Oct 16, 2026
  2. Oct 23, 2026SolicitationDue Oct 30, 2026

    SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions. AMENDMENT 01 The following addendum is issued for Request for Quotation: 369006_X-Ray_Imaging_Detector_System. This amendment provides answers to supplier questions and clarifies the technical requirements and competition basis. This amendment must be acknowledged. Failure to acknowledge all amendments may make a proposal non-responsive. Suppliers shall confirm whether their previously submitted proposal remains unchanged. If the clarification results in a change, please submit a revised proposal. All other terms and conditions of the Request for Quotation remain unchanged. Supplier Questions and SLAC Responses 1. Is the detector intended for an industrial application or for research use, specifically X-ray diffraction? SLAC Response: The detector is intended for X-ray diffraction research. 2. Is this purchase replacing an existing detector? If yes, please provide the current detector model and original serial number so suppliers can confirm compatibility. SLAC Response: This purchase is not replacing an ex

Similar open contracts