Mosquito Lake Control Tower Roof Replacement
See the original posting, the buyer’s contact details, and thousands more contracts like this one
Free account. Already have one? Log in
Extended to Oct 30, 2026 by a later notice
Description
This is a Presolicitation Notice only. This is not a Solicitation (Request for Quote). No purchase order will be issued from this announcement. Any applicable attachments for this project (i.e. Drawings) will be issued at the time of the Solicitation, not during this notice. This procurement is a 100% Small Business Set-Aside. All interested and capable offerors are encouraged to submit a quote. Project Description The U.S. Army Corps of Engineers (USACE), Pittsburgh District has a project that involves the complete replacement of the standing seam metal roof on the Control Tower Building at Mosquito Creek Lake in Cortland, Ohio. The work is to be completed within 365 calendar days after written Notice to Proceed (NTP). Rough Estimate of this non-commercial construction project is between $150,000.00 and $350,000.00. The work includes rerouting existing vent and exhaust pipes through the masonry side wall, installing a new gutter system, and integrating a new, certified, non-penetrating Lightning Protection System. Below are the major components of the work in more detail: Major Components of Work Demolition and Disposal: This phase requires the complete removal and legal disposal of the existing standing seam metal roof panels, box gutter, scuppers, and the old lightning protection system. All materials will be removed down to the underlying concrete roof slab. Structural Sub-Framing Refurbishment: The contractor must inspect all existing light-gauge, cold-formed metal sub-framing. Any framing members exhibiting visible deformation or a cross-sectional area loss of 25% or more due to corrosion must be replaced (up to 95 linear feet). All remaining sub-framing must be cleaned of surface rust by wire-brushing and finished with a suitable protective coating. Roof Deck Repair and Insulation: Before new insulation is applied, the existing concrete roof slab must be repaired, cleaned, and sealed. All repaired areas must pass a 24-hour flood test to verify they are watert…
Notice history (4)
- Aug 19, 2026PresolicitationDue Sep 3, 2026Viewing
- Sep 24, 2026SolicitationDue Oct 26, 2026
Mosquito Lake Control Tower Structural Standing Seam Metal Roof Replacement
- Oct 16, 2026SolicitationDue Oct 26, 2026
Mosquito Lake Control Tower Structural Standing Seam Metal Roof Replacement
- Oct 23, 2026SolicitationDue Oct 30, 2026
Mosquito Lake Control Tower Structural Standing Seam Metal Roof Replacement